MODEL
|
LPV-60-12
|
OUTPUT
|
DC VOLTAGE
|
12V
|
RATED CURRENT
|
5A
|
CURRENT RANGE
|
0~12A
|
RATED POWER
|
60W
|
RIPPLE & NOISE(max).Note.2
|
120mVp-p
|
VOLTAGE ADJ.RANGE
|
~
|
VOLTAGE TOLERANCE Note.3
|
±1.0%
|
LINE REGULATION Note.4
|
±0.5%
|
LOAD REGULATION Note.5
|
±0.5%
|
SETUP,RISE TIME
|
500ms,20ms/230VAC 500ms,20ms/115VAC at full load
|
HOLD UP TIME(Typ.)
|
30ms/230VAC 25ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
85~364VAC OR 248~373VDC
|
FREQUENCY RANGE
|
47~63HZ
|
EFFICIENCY(Typ.)
|
86%
|
AC CURRENT(Typ.)
|
2A/115VAC 1.2A/230VAC
|
INRUSH CURRENT(Typ.)
|
COLD START 36A
|
LEAKAGE CURENT
|
<2mA/240VAC
|
PROTECTION
|
OVERLOAD
|
110~150% rated output power
|
Protection type: C an be con tinued, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
~
|
Protection type : Shut down, recovers automatically after temperature goes down
|
ENVIRONMENT
|
WORKING TEMP.
|
-20~+60°C (Refer to "Derating Curve")
|
WORKING HUMIDITY
|
20~90% RH non-condensing
|
STORAGE TEMP HUMIDITY
|
-40~+85°C 10~95%RH
|
TEMPCOEFFICIENT
|
±0.03% /°C(0~50 °C )
|
VIBRATION
|
10~500HZ,2G10min/1cycle,60min.each alongX,Y,Zaxes
|
SAFETY & EMC(Note 7)
|
SAFETY STANDARDS
|
UL60950-1, CB(IE60950-1),CCC GB4943.1:2011 approved
|
WITHSTAND VOLTAGE
|
l/P-o/P:3KVAC; l/P-FG:2KVAC; O/P-FG:0.5KVAC
|
ISOLATIONRESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC / 25°C/ 70% RH
|
EMC EMISSION
|
Compliance to EN55015, FCC part 15 class B
|
EMC IMMUNITY
|
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
|
OTHERS
|
MTBF
|
320.7Khrs min MIL-HDBK-217F(25°C)
|
DIMENSION
|
159*98*38mm(L*W*H)
|
PACKING
|
0.55Kg; 30pcs/17.5Kg/0.97CUFT
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation.
4.Constant current operation region is within 60% ~100% rated output voltage, and the output power must be more than 60% rated output power.This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5.Derating may be needed under low input voltages. Please check the static characteristics for more details.
6.Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
|